• GHS Mains Breaker kit (for DIN Rail)
  • AI801
  • AI810
  • AI815
  • AI820
  • AI825
  • AI830A
  • AI835A
  • AI843
  • AI845
  • AI890
  • AI893
  • AI895
  • AO801
  • AO810V2
  • AO815
  • AO820
  • AO845A
  • AO890
  • AO895
  • BC810K02
  • BC820K02
  • CI801
  • CI840A
  • CI853 (Comli)
  • CI853 (MODBUS RTU)
  • CI854A
  • CI855
  • CI856
  • CI857
  • CI858
  • CI865
  • CI867
  • CI868
  • CI869
  • CI871
  • CI873
  • DI801
  • DI802
  • DI803
  • DI810
  • DI811
  • DI814
  • DI818
  • DI820
  • DI821
  • DI825
  • DI828
  • DI830
  • DI831
  • DI840
  • DI885
  • DI890
  • DO801
  • DO802
  • DO810
  • DO814
  • DO815
  • DO818
  • DO820
  • DO821
  • DO828
  • DO840
  • DO890
  • DP820
  • DP840
  • NE801
  • NE802
  • NE810
  • NE820
  • NE840
  • NE870
  • NE871
  • PM851A
  • PM856A
  • PM858
  • PM860A
  • PM861A
  • PM862
  • PM864A
  • PM866A
  • PM891
  • PP871
  • PP874
  • PP874K
  • PP874M
  • PP877
  • PP877K
  • PP880R
  • PP882
  • PP885
  • PP885H
  • PP885M
  • PP885R
  • PP886H
  • SD822Z
  • SD831
  • SD832
  • SD833
  • SD834
  • SS822Z
  • SS823
  • SS832
  • TB820V2
  • TB825 (Multi Mode)
  • TB826 (Single Mode)
  • TB840A
  • TB842
  • TU807
  • TU810V1
  • TU811V1
  • TU812V1
  • TU813
  • TU814V1
  • TU818
  • TU819
  • TU830V1
  • TU831V1
  • TU833
  • TU835V1
  • TU836V1
  • TU837V1
  • TU838
  • TU839
  • TU840
  • TU841
  • TU842
  • TU843
  • TU844
  • TU845
  • TU846
  • TU847
  • TU848
  • TU849
  • TU850
  • TU851
  • TU852
  • TU854
  • TU890
  • TU891
System Configuration

Find products

NE871

NE871 is an industrial router which also acts as a firewall. The router/firewall can be utilized to segment a system in to network areas and also security zones. NE871 is primarily intended to connect a client server network to a plant network or to a DMZ (demilitarized zone).

The concept of security zoning is described in IEC62443. In short, security zoning is a method to segment a system into zones with different security levels. A security level is complied with by implementing a combination of security countermeasures. The reason why it potentially could make sense to divide a system into security zones, which comply with different security levels, could be that the risk for different parts of the system varies. Another could be that the impact of a potential incident varies.

NE871 supports RNRP (Redundant Network Routing Protocol), which enables 800xA to have two physically separate networks, and thereby avoid single point of failure.

Features and benefits

• NE871 has redundant power supply and alarm function
• Wide operating voltage range (16 VDC to 60 VDC)
• Back end holds a casted DIN-clip for stable mounting on a DIN-rail.
• Digital IO for monitoring
• Console port for management using CLI
• USB port for easy save and load system configuration
• 3 x RJ-45 Ethernet 1000BaseTX connectors
• Status LEDs

Link to SFP table